52 actions. What changed?

The Laboratory Quality Briefing · IV · 20 November 2026

If you reopened one of last month’s completed quality actions, could you show what improved? A new procedure and a signed training record tell you what was done. The harder question is whether the original problem is now less likely to happen.

From the literature

Färlin-Helin and colleagues tested failure mode and effect analysis (FMEA) in a Finnish paediatric department. Staff mapped processes, considered what could go wrong and agreed priorities. The figure shows what they completed.

Of 19 processes suggested for FMEA, eight assessments were completed, seven lacked staff time, three were not considered necessary and one had no suitable process identified. The completed assessments identified 59 possible failures and 52 planned actions.
Processes suggested for assessment and reasons why some were not completed. Source: Färlin-Helin et al., 2026.

What did the teams propose?

Specific proposals included making messages visible to all staff using a digital patient app, placing an experienced system user on every shift during an electronic-record rollout, and changing bottles to address four of five problems in milk pasteurisation.

These are useful proposals because each changes something identifiable in the work: who can see a message, who is available to help, or which equipment is used. That makes it possible to ask a focused follow-up question. Did messages stop being missed? Could staff get help on every shift? Did the replacement bottles remove the problems they were meant to address?

What does the study establish?

The authors concluded that FMEA suited these processes. They did not report whether the 52 actions were implemented or improved outcomes. The researcher who led the work also worked in that department.

My reading is that the paper offers a practical way to turn a broad concern into specific changes. It also shows why that work needs protected time. Planning an assessment is easy; getting the right people together, agreeing what should change and checking the result all require someone’s time. A laboratory should plan those later checks when it agrees the action.

Read the open-access paper · Färlin-Helin et al. Journal of Evaluation in Clinical Practice, 2026. doi:10.1111/jep.70722.

A laboratory example: the message says “sent”

Take an urgent potassium result sent to a clinician whose shift has ended. The laboratory system records “message sent”, but nobody confirms receipt. This is closely related to the paper’s proposal about message visibility: information can be available somewhere without reaching the person who needs to act.

The failure is specific. The contact details do not identify the team covering that shift, and there is no clear owner for chasing an unanswered message. Repeating the instruction to “communicate urgent results” leaves both gaps in place.

A more useful change would identify the responsible team for each shift, record confirmation of receipt and name who follows up when confirmation is missing. The laboratory would use its agreed communication times and escalation procedure.

What would you look for in the records?

Suppose you review 30 urgent results before the change and another 30 afterwards. Check the communication records, including results sent outside normal hours.

CheckBeforeAfter
Message sent30/3030/30
Receipt confirmed on time18/3028/30
Late or missing replies followed up3/122/2
Receipt not confirmed at review9/300/30
Worked audit: 30 urgent results before the change and 30 afterwards.

The “message sent” total is unchanged. On its own, that measure would suggest there was never a problem. The other rows tell a different story.

Before the change, receipt was confirmed on time for 18 of 30 results. Twelve replies were late or missing, and only three were followed up. Nine results still had no confirmed receipt when the records were reviewed.

After the change, 28 of 30 were confirmed on time. The two late replies were both followed up, and receipt was recorded for both. That gives the team a useful conclusion: the follow-up process is being used, while timely acknowledgement still needs attention. The next review should examine why those two replies were late.

Close the action with an answer

The useful question is no longer “Have we updated the procedure?” It is “Can we show that urgent results reach the responsible team, and that missing replies are followed up?” The table provides evidence for both parts of that question.

For your next quality meeting, choose one completed action and ask for a short account of what changed, what was checked and what still needs attention. If the record ends with “staff trained”, the team has more to find out.

FMEA can help a team decide what to change. A completed action should also tell the next reviewer what happened after the change was made.

On the website: what’s new

New help inside taught courses. You can now ask the course AI assistant for a simpler explanation, a laboratory example or a question to check your understanding. Select “Ask about this lesson” while studying; try it in APS01, our foundation course on analytical performance specifications. The assistant is available through Member Learning.

A second applied case is now live. The QC is back in range — can you resume testing? was added after the previous Briefing. Investigate a failure after a reagent-pack change. Decide whether testing can restart and what to do with earlier results. Members can save their answers, compare their reasoning with the expert discussion and download a case record for continuing professional development (CPD).

Further learning

If you are new to risk-based thinking, the free Risk-based approaches email course provides five introductory emails over ten days. It explains how laboratory problems could lead to harm, what helps prevent that harm and how to check whether those safeguards work. Short reflections help you apply the ideas.

For your CPD record, consider: What would make me reopen an action that my laboratory has marked complete? Choose a real example. Describe what was changed, what you know about how it works and what you still need to check.

Stephen MacDonald PhD FRCPath
Pathology Uncertainty · Practical statistics and analytical quality across laboratory medicine


Discover more from Pathology Uncertainty