Analytical performance specifications: what quality is needed?

An analytical performance specification (APS) describes the measurement quality needed for a particular use.

1 · Understand APS   →   2 · Understand verification

Understand what an APS means, where it comes from and why it belongs before a verification decision.

Free APS email course · Five short emails

What does “good enough” mean?

A short introduction to measurement-quality requirements, precision, bias and the different meanings of an acceptable result. Clear explanations, familiar examples and occasional reflections.

Explore the free APS course →

About three minutes per email.
No calculations or workbook.

By Stephen MacDonald · Updated 2 October 2026

Start with the use of the result

A test may help make a decision near a threshold or monitor change over time. The analytical performance needed for those uses may differ. “The analyser performs well” is therefore incomplete: well enough for which purpose, and at which concentrations?

An APS connects that purpose to a requirement, such as a limit for imprecision or bias. It provides a basis for judging performance; the performance you happen to observe does not, by itself, define what is acceptable.

Five terms that answer different questions

TermThe question it answers
Performance specificationWhat analytical quality is needed?
Manufacturer’s claimWhat performance does the manufacturer state?
Local study resultWhat did our study observe?
IQC control limitWhen should routine control results trigger a response?
EQA assessment limitHow does this scheme judge a submitted result?

These quantities can inform one another, but they are not interchangeable. A total-error allowance is not automatically a limit for CV, bias or measurement uncertainty. Compare the same characteristic, units and conditions.

Where do specifications come from?

The EFLM Milan consensus describes three models. [1]

  • Clinical outcomes: how analytical performance affects clinical decisions and patient outcomes.
  • Biological variation: analytical variation considered in relation to variation within and between people.
  • State of the art: performance that is technically achievable or achieved by a defined group of laboratories.

The appropriate model depends on the test’s use and the quality and relevance of the evidence. A published number is not automatically suitable for every population or concentration. Achievable performance is not necessarily sufficient for a clinical need.

One example: the right question, wrong concentration

Fictional example. A laboratory introduces an assay used near a low decision threshold. It has convincing precision results at a much higher concentration.

Those results describe the condition studied. They do not establish the quality needed, or the performance achieved, near the threshold. The laboratory first needs to identify the relevant requirement there, then obtain evidence that addresses it.

The lesson: “good precision” only becomes useful evidence when it is connected to the intended use. The verification guide continues this example.

How APS connects to verification

APS asks what is needed. Verification asks whether specified requirements are met. A manufacturer’s claim and a requirement for your intended use may not be the same.

Before judging a study, be clear which requirement it addresses and why that requirement is appropriate. Choose the criterion before seeing the results. If it is not met, investigate the evidence and the proposed use; do not select a more convenient limit simply to obtain a pass.

Ready to apply the ideas?

The next level is designing a study, analysing its data and writing a defensible conclusion. Planned paid learning will bring these together through guided cases, datasets and editable working documents.

This module is not yet open for enrolment. Tell us which part you need help with and mention “APS–verification” in your enquiry.

An enquiry does not enrol you on a course or subscribe you to the newsletter.

Sources and boundaries

This is a conceptual introduction, not an assay-specific specification or a study protocol. The example is original and fictional. Follow applicable guidance and local governance when applying the ideas.